- Brand Name: Jessinie
- High-concerned chemical: None
- Origin: Mainland China
- Output: Digital Sensor
- Theory: Hall Sensor
- Type: Biosensor
- is_customized: Yes
- Use: Pressure Sensor
- Material: Metal
Electronic scale sensor (range 1/5/10/20kg)
Product details:
Technical parameters:
1. Range: 10kg
2. Output sensitivity: 1.0±0.1mV/V
3. Nonlinearity: 0.03%F.S
4. Hysteresis: 0.03%F.S
5. Repeatability: 0.03%F.S
6. Creep: 0.05%F.S/3min
7. Zero output: -0.15±0.05mV/V
8. Output impedance: 1000±10 ohms
9. Four-corner error: 0.05%F.S
10. Temperature sensitivity drift: 0.03%F.S/10℃
11. Zero temperature drift: 0.3%F.S/10°C
12. Product size: 75×12.7×12.7mm
Technical parameters:
1. Range: 10kg
2. Output sensitivity: 1.0±0.1mV/V
3. Nonlinearity: 0.03%F.S
4. Hysteresis: 0.03%F.S
5. Repeatability: 0.03%F.S
6. Creep: 0.05%F.S/3min
7. Zero output: -0.15±0.05mV/V
8. Output impedance: 1000±10 ohms
9. Four-corner error: 0.05%F.S
10. Temperature sensitivity drift: 0.03%F.S/10℃
11. Zero temperature drift: 0.3%F.S/10°C
12. Product size: 75×12.7×12.7mm

Principle of use:
A weighing sensor is actually a device that converts mass signals into measurable electrical signal outputs. The weighing sensor consists of an elastic body (deformation block) and a strain gauge. Under the load of a heavy object, the elastic body deforms, causing the strain gauge attached to the surface of the elastic body to deform as well. Finally, the specific weight of the heavy object is obtained by processing the induction value of the strain gauge.
Application wiring instructions:
Power positive (E+) red, power negative (E-) black, signal positive (S+) white, signal negative (S-) green
Note: If there is a negative number during installation, please swap the signal line
Specific description:
Strain gauges are arranged on both sides of the elastic body (deformation block); the cross section of the elastic body is square, two intersecting through holes are arranged on one side of the elastic body, and strain gauges are arranged on the other two sides of the elastic body. The elastic body is provided with mounting threaded holes at both ends where the strain gauges are arranged, and the two intersecting through holes have the same diameter and are located in the middle of the deformation block.
The two intersecting through holes form an intersecting surface, and the strain gauge is arranged on the intersecting surface.
The strain gauges are symmetrically arranged on both sides of the intersecting surface.
The center distance of the intersecting holes is 7.0mm.
Two mounting threaded holes are arranged at both ends of the deformation block, and the specifications are both M4.
The strain gauge is glued on the flat end surface of the deformation block.
The strain gauge is connected to the terminal with enameled wire and protected by soft glue.
A wire is connected at the terminal, and soft glue is applied at the connection position for protection.
The soft glue completely covers the strain gauge.
Installation Instructions:
A weighing sensor is actually a device that converts mass signals into measurable electrical signal outputs. The weighing sensor consists of an elastic body (deformation block) and a strain gauge. Under the load of a heavy object, the elastic body deforms, causing the strain gauge attached to the surface of the elastic body to deform as well. Finally, the specific weight of the heavy object is obtained by processing the induction value of the strain gauge.
Application wiring instructions:
Power positive (E+) red, power negative (E-) black, signal positive (S+) white, signal negative (S-) green
Note: If there is a negative number during installation, please swap the signal line
Specific description:
Strain gauges are arranged on both sides of the elastic body (deformation block); the cross section of the elastic body is square, two intersecting through holes are arranged on one side of the elastic body, and strain gauges are arranged on the other two sides of the elastic body. The elastic body is provided with mounting threaded holes at both ends where the strain gauges are arranged, and the two intersecting through holes have the same diameter and are located in the middle of the deformation block.
The two intersecting through holes form an intersecting surface, and the strain gauge is arranged on the intersecting surface.
The strain gauges are symmetrically arranged on both sides of the intersecting surface.
The center distance of the intersecting holes is 7.0mm.
Two mounting threaded holes are arranged at both ends of the deformation block, and the specifications are both M4.
The strain gauge is glued on the flat end surface of the deformation block.
The strain gauge is connected to the terminal with enameled wire and protected by soft glue.
A wire is connected at the terminal, and soft glue is applied at the connection position for protection.
The soft glue completely covers the strain gauge.
Installation Instructions:

The sensor outlet is connected to the upper plate, and the other end of the sensor is connected to the base, with the middle suspended in the direction as shown.
Note: A protective device (such as a thimble) can be installed under the other end of the sensor to prevent damage to the sensor after overload. (Safety overload 150%, limit overload 200%)
Note: A protective device (such as a thimble) can be installed under the other end of the sensor to prevent damage to the sensor after overload. (Safety overload 150%, limit overload 200%)
| Color | 10KG With HX711, 1KG With HX711, 20KG With HX711, 5KG With HX711, Only 10KG Sensor, Only 1KG Sensor, Only 20KG Sensor, Only 5KG Sensor, Only HX711 Module |
|---|---|
| Brand Name | Jessinie |
| High-concerned chemical | None |
| Origin | Mainland China |
| Output | Digital Sensor |
| Theory | Hall Sensor |
| Type | Biosensor |
| is_customized | Yes |
| Use | Pressure Sensor |
| Material | Metal |